Hello!

There is a fundamental principle in BIRD that one BIRD table may be synced to at most one kernel table. Use BIRD pipe pseudoprotocol to duplicate the routes to more BIRD tables.

This concept may be changed in future, yet not in near future.

Maria

On June 1, 2020 7:58:39 PM GMT+02:00, Matt Corallo <birdlist@as397444.net> wrote:
When trying to sync a BIRD routing table to multiple kernel routing tables (with different export filters, obviously),
BIRD refuses with, eg, "Kernel syncer (v6kern) already attached to table master6". Is this something that is fundamental
or would be it easy to address this by allowing it if the "kernel table" field has a different value?

Thanks,
Matt

--
Sent from my Android device with K-9 Mail. Please excuse my brevity.