On Mon, Dec 17, 2012 at 02:17:59PM +0200, Javor Kliachev wrote:
Hello,
We're trying to implement in our RS configuration additional "Collector" table.
After making the changes began to generate the following message to our log file like this and our log file become too large for a very short time :
17-12-2012 13:57:16 <ERR> Pipe collision detected when sending 120.28.62.0/24 to table Collector 17-12-2012 13:57:16 <ERR> Pipe collision detected when sending 120.28.62.0/24 to table Collector
..
Everything other works fine. We would like to understand if there is something wrong in our configuration?
There is a problem that you have many paths for router from BGP to collector table: Standard: RO_149 -> T65050 -> C65050 -> Collector Unexpected: RO_149 -> T65050 -> master -> Txxxxx -> Cxxxx -> Collector You should add import filter for Cxxxx to allow only routes received from associated BGP connection and not the routes received through master table. -- Elen sila lumenn' omentielvo Ondrej 'SanTiago' Zajicek (email: santiago@crfreenet.org) OpenPGP encrypted e-mails preferred (KeyID 0x11DEADC3, wwwkeys.pgp.net) "To err is human -- to blame it on a computer is even more so."